AVAILABLE MODELS

PRC from the side

PRC-1200

Recommended for spaces up to 2,500 cubic feet.

Full specs at bottom of page.

PRC Air Purifier

PRC-800

Recommended for spaces up to 1,667 cubic feet.

Full specs at bottom of page.

HOW IT WORKS

HEAVY DUTY CONSTRUCTION: Heavy 12 and 16-guage, fully welded steel construction with durable powdercoat finish, backed by our quality-built guarantee.

“EASY LOAD” FILTER SYSTEM: Top-load filter system allows filters to be removed in seconds. Vertical filter design enables dust to be shed more easily, extending filter life.

DUAL FILTRATION SYSTEM: Air passes through a two-stage filtration system, with a MERV 8 carbon prefilter to remove larger contaminants and odor and a MERV 15 or HEPA filter to remove smaller contaminants.

BUILT-IN ACOUSTICAL SOUND PLENUM: High-density foam barriers and built-in acoustical bass traps are engineered for quiet operation—just 70 dBA!

HIGH PERFORMANCE BLOWER: The aluminum Acoustafoil blower (inside) is the heart of the RoboVent PRC. This high-performance blower is engineered for high output air volume.

LOCKING WHEELS: Two-stage locking castor wheels lock unit in all four directions.

RoboVent N95 and filter

THE FILTER MEDIA

Air will flow through two stages of air filtration before exhausting into the room. The PRC comes standard with a MERV 8, carbon pre-filter and has three options for interior cartridge filter media, choose the best for your application:

  • Nanofiber, MERV15; 254 sq. ft. Media Area
  • HEPA E11; 170 sq. ft. Media Area (Comparable to N95 mask media)
  • HEPA H13; 170 sq. ft. Media Area (Comparable to P100 mask media)
RoboVent Dust Fume Sizes Chart

WHAT AM I FILTERING?

The type of particulate we capture in air filtration systems is often driven by the actual media being used inside the filtration system. It’s important to know the make-up of the particle, it’s relationship with airflow patterns in terms of how the air conveys the particle and the micron size.

TYPICAL ENVIRONMENTS

The PRC is suitable for any indoor setting and typically used in commercial and light industrial settings as a supplemental, portable system to existing HVAC filtration systems. When the volume of space exceeds 2,500 cu ft, we recommend multiple units or perhaps considering a larger, more centralized system.

Example Areas may include but not be limited to:

Assisted Living Facilities |  Churches | Convenience Stores | Control Panel Rooms |  Fire Stations  |  Food Prep Areas & Kitchens | Grocery Stores  | Gyms | Laboratories |  Laundry Facilities |  Light Assembly Areas | Marijuana Dispensary & Cannabis Operations  |  Municipal Buildings | Nursing Facilities | Operating Rooms  |  Packaging Areas |  Patient Receiving & Discharge Spaces  |  Police Stations | Physical Therapy Clinics  |  Print Shops  |  Prisons & Jails  |  Repair Shops  |  Shipping Areas | Waiting Rooms  |  Warehouses  |  Workshops  |  Worship Centers

RoboVent Environments
RoboVent Air Circulation

HOW OFTEN SHOULD I RECIRCULATE THE AIR IN THE ROOM?

If the return air from the purifier does not need to be exhausted outside, such as in an emergency room setting or a triage area, it could be based on user preference. Do you want to refresh the air 1x per hour? 100x per hour?  It’s really up to you. Use the calculator below to make your determination.

Enter your room dimensions below to see how many changes per hour a single PRC unit. You can also just enter a total room volume if you don’t have specific dimensions.

If for some reason the calculator above isn’t working, don’t fret. The following calculation gives you an idea of the refresh rate a single RoboVent PRC can provide:

  • Room Height x Room Length x Room Width = Room Volume
  • RoboVent PRC = 1200 CFM or 800 CFM
  • Room Volume ÷ CFM = number of minutes per room change
  • 60 minutes ÷ number of minutes per room change = Room Change per Hour

NEED CLEAN AIR FAST?

The PRC can be ready to ship in one week from the time the order is entered in our system.


Actual delivery date will be driven by number of units purchased and specific shipping location(s).

PRC SPECIFICATIONS

PRC-1200

Capacity:1200 CFM
Motor:1.5 HP, Direct Drive
Voltage:Single phase, 110V, 60Hz
Full Load Amps:20.0
Blower:Reverse inclined high performance blower wheel
Sound Level:71 dBA
Silencing:Integral acoustical plenum with low frequency dampening
Controls:Manual on/off switch, minihelic filter conditon gauge
Cabinet Dimensions:53" H x 23" L x 31" D
Shipping Weight:350 lbs.
Carbon Pre-Filter:2" x 20" x 24" MERV 8
Primary Filter Options:Nanofiber, MERV 15; 254 sq. ft. Media Area

HEPA E11; 170 sq. ft. Media Area (>95% Efficiency, comparable to N95 mask)

HEPA H13; 170 sq. ft. Media Area (>99.95% Efficiency, comparable to P100 mask)
Options:CSA Certification - CSA-100

PRC-800

Capacity:800 CFM
Motor:.75 HP, Direct Drive
Voltage:Single phase, 110V, 60Hz
Full Load Amps:13.8
Blower:Reverse inclined high performance blower wheel
Sound Level:67 dBA
Silencing:Integral acoustical plenum with low frequency dampening
Controls:Manual on/off switch, minihelic filter conditon gauge
Cabinet Dimensions:36" H x 20" L x 39" D
Shipping Weight:275 lbs.
Carbon Pre-Filter:2" x 20" x 24" MERV 8
Primary Filter Options:Nanofiber, MERV 15; 254 sq. ft. Media Area

HEPA E11; 170 sq. ft. Media Area (>95% Efficiency, comparable to N95 mask)

HEPA H13; 170 sq. ft. Media Area (>99.95% Efficiency, comparable to P100 mask)
Options:CSA Certification - CSA-100

DROP US A LINE

Contact RoboVent today to start building your custom dust collection system.